Calibration Kit, VNA calibration,open-kit,short-kit,load
Calibration Kit, VNA calibration,open-kit,short-kit,load
Calibration Kit, VNA calibration,open-kit,short-kit,load
ETES-PRE Calibration Kit | RF Calibration Kit and RF cables | Ecmicrowave
ETES-PRE Calibration Kit | RF Calibration Kit and RF cables | Ecmicrowave
ETES-PRE Calibration Kit | RF Calibration Kit and RF cables | Ecmicrowave

ETES-PRE Calibration Kit | RF Calibration Kit and RF cables | Ecmicrowave

  • LOAD SHORT OPEN N 6GHz (F)
  • LOAD SHORT OPEN N 6GHz (M)
  • LOAD SHORT OPEN N 9GHz (F)
  • LOAD SHORT OPEN N 9GHz (M)
  • LOAD SHORT OPEN 3.5mm 6GHz (F)
  • LOAD SHORT OPEN 3.5mm 6GHz (M)
  • LOAD SHORT OPEN 3.5mm 9GHz (F)
  • LOAD SHORT OPEN 3.5mm 9GHz (M)

RF Calibration Kit ETES-PRE 

Coaxial mechanical Calibration kit ,used in the VNA calibration and test

Precise, Durable

Coaxial mechanical Calibration kit is wildly used in the

Reliable

RF Calibration Kit test port made by stainless steel extends the service life.

Under typical conditions, the Calibration kit can be used over 2000 times, which is far more than the 500-times standard by IEC and MIL

Confidence

Crafted details bring perfect use experience.

 Advanced standard calibration during manufacture, 

Ensured customer-confidence in each calibration and test.

 VNA calibration and test, it is composed by a series of open-kit,short-kit and load.


Ideal connection interface, excellent electrical performance



Model:ETES-PRE Calibration Kit
Maximum:-


send inquiry1


ETES-PRE Calibration Kit


Precise, Durable

Coaxial mechanical Calibration kit is wildly used in the VNA calibration and test, it is composed by a series of open-kit,short-kit and load.

Ideal connection interface, excellent electrical performance


Reliable

The test port made by stainless steel extends the service life.

Under typical conditions, the Calibration kit can be used over 2000 times, which is far more than the 500-times standard by IEC and MIL


Confidence

Crafted details bring perfect use experience.

 Advanced standard calibration during manufacture, 

Ensured customer-confidence in each calibration and test.


Selection Guide

P/N

Type

Connector

Freq.

(GHz)

Specification

Mating Cycles (times)

Coupling Torque

(Nm)

Open-end Wrench size

(mm)

ETES-PRE-NM-O-06

Open

N-M

6

Phase deviation≤±0.6°

>3000

1.3~1.7

19

ETES-PRE -NF-O-06

N-F

ETES-PRE-NM-S-06

Short

N-M

6

Phase deviation≤±0.6°

>3000

1.3~1.7

19

ETES-PRE-NF-S-06

N-F

ETES-PRE-NM-L-06

Load

N-M

6

VSWR≤1.025

>3000

1.3~1.7

19

ETES-PRE-NF-L-06

N-F

ETES-PRE-NM-O-09

Open

N-M

9

Phase deviation≤±0.8°

>3000

1.3~1.7

19

ETES-PRE-NF-O-09

N-F

ETES-PRE-NM-S-09

Short

N-M

9

Phase deviation≤±0.8°

>3000

1.3~1.7

19

ETES-PRE-NF-S-09

N-F

ETES-PRE-NM-L-09

Load

N-M

9

VSWR≤1.032

>3000

1.3~1.7

19

ETES-PRE-NF-L-09

N-F

ETES-PRE-35M-O-06

Open

3.5-M

6

Phase deviation≤±0.6°

>2000

0.8~1.1

8

ETES-PRE-35F-O-06

3.5-F

ETES-PRE-35M-S-06

Short

3.5-M

6

Phase deviation≤±0.6°

>2000

0.8~1.1

8

ETES-PRE-35F-S-06

3.5-F

ETES-PRE-35M-L-06

Load

3.5-M

6

VSWR≤1.025

>2000

0.8~1.1

8

ETES-PRE-35M-L-06

3.5-F

ETES-PRE-35M-O-09

Open

3.5-M

9

Phase deviation≤±0.8°

>2000

0.8~1.1

8

ETES-PRE-35F-O-09

3.5-F

ETES-PRE-35M-S-09

Short

3.5-M

9

Phase deviation≤±0.8°

>2000

0.8~1.1

8

ETES-PRE-35F-S-09

3.5-F

ETES-PRE-35M-L-09

Load

3.5-M

9

VSWR≤1.032

>2000

0.8~1.1

8

ETES-PRE-35F-L-09

3.5-F